Attackers exploited vulnerabilities in Mitel’s MiCollab conferencing software before a fix was available, security researchers report, giving organizations a reason to investigate past activity as well as install the patch.
The five flaws affect the Audio, Web and Video Conferencing (AWV) component of MiCollab 10.3 (10.3.0.18) and earlier. Mitel published a fix on November 16; the US Cybersecurity and Infrastructure Security Agency added all five vulnerabilities to its known-exploited catalog on November 25, according to the Canadian Centre for Cyber Security.
In one intrusion, an attacker went from an initial request to a command-running web shell in 12 minutes, obtained root access within 30 minutes and used credentials stored for MiCollab’s directory connection shortly afterward, Accenture APEX Labs reported. The activity began on November 15, before Mitel’s advisory. A successful update closes the known vulnerabilities but does not remove access an intruder may already have established.
Which MiCollab versions need attention?
Mitel’s advisory lists MiCollab 10.3 (10.3.0.18) and earlier as affected. Administrators should upgrade to 10.3 (10.3.0.18) and apply the separate security patch, or upgrade to a later release that includes the update. Being on the 10.3.0.18 base release alone is not enough. Mitel’s knowledge base article KB000129195 has installation instructions; customers without access should contact their authorized partner.
If patching cannot be completed promptly, Mitel recommends restricting external access to the AWV component as a temporary mitigation. Plan the restriction around legitimate conferencing and operational needs, and do not treat it as a substitute for the fix. The vendor’s advisory covers supported products and does not assess versions that have reached end of support; owners of older installations should seek a supported migration path.
What the five vulnerabilities allow
All five can be reached without authentication, although individual flaws have different conditions. Mitel rates two critical: CVE-2026-133323 is a blind operating-system command injection, while CVE-2026-133303 is an XML injection that can execute commands using malicious content staged on the system beforehand.
The other three cover arbitrary file upload (CVE-2026-133275), limited unauthorized access to sensitive information under specific conditions (CVE-2026-133311), and an authentication bypass permitting unauthorized actions within the application (CVE-2026-133324). Mitel warns that combining vulnerabilities can amplify their impact. Accenture could not determine which individual flaw was used for initial access in a second observed organization, so defenders should not assume every incident follows one exact sequence.
Why the investigation must go beyond the appliance
In the incident reconstructed by Accenture, the attacker recovered credentials from MiCollab’s LDAP connector and authenticated to a domain controller 32 minutes after the first observed request. The attacker then collected directory information, obtained service tickets for offline password cracking and harvested credentials from internal file shares. About 20 hours after the first request, the attacker reached a backup server and a business database server, dumping and uploading data.
That sequence makes the permissions and stored credentials on a communications server important to the response. Security teams should identify the directory connector account and other credentials available to the appliance, review their use and privileges, and investigate connected identity, backup and database systems where evidence warrants. Coordinate any credential rotation with incident responders and system owners to avoid disrupting dependent services.
Accenture also observed a second organization’s MiCollab server communicating with the same attacker infrastructure from November 9. The researchers have not established how that server was compromised or what its traffic contained. Their report assesses that AI-assisted tooling may have driven parts of the intrusion, but sampled network data did not establish exactly how the attacker used the AI services.
Where to look for signs of compromise
Preserve relevant evidence and review upstream proxy, firewall and network records alongside host artifacts. In the investigated case, the attacker filtered web-shell requests from local web, error and administration logs; clean local logs alone therefore cannot rule out compromise. The attack also passed through an internet-facing reverse proxy, so the presence of a proxy is not proof that the AWV component was protected.
Accenture’s report provides dated indicators and detection patterns, including unfamiliar POST requests under /awcuser/cgi-bin/ followed by requests for newly created files under /pictures/, plus suspicious archives or tooling in /tmp. Check the full report for context and indicator dates: an IP address can have belonged to a different tenant earlier, and attackers can change infrastructure. A lack of matches is not proof of safety.
Prioritize systems that exposed AWV externally, including through a gateway or proxy, and involve incident-response specialists if suspicious activity is found. Alongside production appliances, check standby or recovery installations and confirm their patch status before returning them to service.